Availability: | |
---|---|
Quantity: | |
Eos 3H-A
NOBLE LASER
Elight:
The E-Light technology fully combines the advantages of optical energy and radio frequency. With the impedance difference in skin and pre-heat produced when the skin selectively absorbs optical energy, the targeted tissue absorbs radio frequency with lower optical energy. So with a very low risk of side effects-pigment lesion, blistering-generally caused by higher optical energy, we are able to achieve good result with comfortable treatment. The traditional IPL device can only reach 2mm into the skin, however, the E-light creates a deep penetration into the dermis about 15mm, which can achieve more applications, especially on wrinkle treatments and skin tightening.
IPL:
IPL (Intense Pulsed Light) adopts the principle that substance absorbs light selectively. As different target tissues absorbs pulsed light with different spectrum and the light acts on pigment. Through photo thermal and actinism, the machine could dispel pigment, concrete blood vessel, burn the hair follicle and stimulate the collagen to regeneration, then it will achieve the aim to dispelling speckles, treating telangiectasis, removing hair and rejuvenating skin. Because the normal skin absorbs little energy, so the treatment is safe.
RF:
It uses 1-40MHz radio frequency to alternate the electric field in the skin from positive to negative. It will produce heat under dermis then the initial collagen denaturation. The adjuvant therapy of 635nm Diode laser greatly promotes the RF treatment effect. Subsequent neocollagenesis then further tightens the dermal tissue and make the skin tightening, smooth and fresh!
Application
1. Acne treatment; Pigmentation treatment; Skin rejuvenation; Vascular therapy; Hair removal
2. Wrinkle removal; Body shaping, Skin tighten; Facial lifting and tightening; Skin rejuvenation, pores lessen, skin whitening
Advantage
1. UK imported xenon lamp for Elight
2. 3 Japanese NCC capacitors
3. USA & German connector of handpiece
Before & After
Specitication
Basic Specification | |
Screen | 8.4~10.4 inch color touch screen |
Cooling System | Air+Water+Semiconductor cooling |
E-light+IPL | |
Type | Super Intense Pulsed Light |
Wavelength | 480-950nm: remove acne |
530 -950nm: pigmentation treatment | |
560 -950nm: skin rejuvenation | |
590-950nm: remove vascular | |
640-950nm: remove hair | |
690-950nm/755-950nm/810-950nm: remove hair (optional) | |
RF Frequency | 3MHz |
RF Energy | 1-100J/cm2 |
IPL Energy | 1~50J/cm2 |
Power Supply Spot Size | Max 2500W |
Filter handpiece: 12*12mm2, 12*30mm2, 13*40mm2, 15*50 mm2 | |
Filter fixed handpiece: 8*40mm2, 14*40mm2, 16*50 mm2 | |
Pulse Number | 1~6T |
Pulse Interval | 1~99ms |
Pulse Width | 0.1~9.9ms |
Discharge Interval | 1~4s |
RF Delay | 1~3s |
Cooling Temperature | -5~5°C |
RF | |
Output Mode | Tripolar |
Energy | 5~450J |
Frequency | 1-40MHz |
Elight:
The E-Light technology fully combines the advantages of optical energy and radio frequency. With the impedance difference in skin and pre-heat produced when the skin selectively absorbs optical energy, the targeted tissue absorbs radio frequency with lower optical energy. So with a very low risk of side effects-pigment lesion, blistering-generally caused by higher optical energy, we are able to achieve good result with comfortable treatment. The traditional IPL device can only reach 2mm into the skin, however, the E-light creates a deep penetration into the dermis about 15mm, which can achieve more applications, especially on wrinkle treatments and skin tightening.
IPL:
IPL (Intense Pulsed Light) adopts the principle that substance absorbs light selectively. As different target tissues absorbs pulsed light with different spectrum and the light acts on pigment. Through photo thermal and actinism, the machine could dispel pigment, concrete blood vessel, burn the hair follicle and stimulate the collagen to regeneration, then it will achieve the aim to dispelling speckles, treating telangiectasis, removing hair and rejuvenating skin. Because the normal skin absorbs little energy, so the treatment is safe.
RF:
It uses 1-40MHz radio frequency to alternate the electric field in the skin from positive to negative. It will produce heat under dermis then the initial collagen denaturation. The adjuvant therapy of 635nm Diode laser greatly promotes the RF treatment effect. Subsequent neocollagenesis then further tightens the dermal tissue and make the skin tightening, smooth and fresh!
Application
1. Acne treatment; Pigmentation treatment; Skin rejuvenation; Vascular therapy; Hair removal
2. Wrinkle removal; Body shaping, Skin tighten; Facial lifting and tightening; Skin rejuvenation, pores lessen, skin whitening
Advantage
1. UK imported xenon lamp for Elight
2. 3 Japanese NCC capacitors
3. USA & German connector of handpiece
Before & After
Specitication
Basic Specification | |
Screen | 8.4~10.4 inch color touch screen |
Cooling System | Air+Water+Semiconductor cooling |
E-light+IPL | |
Type | Super Intense Pulsed Light |
Wavelength | 480-950nm: remove acne |
530 -950nm: pigmentation treatment | |
560 -950nm: skin rejuvenation | |
590-950nm: remove vascular | |
640-950nm: remove hair | |
690-950nm/755-950nm/810-950nm: remove hair (optional) | |
RF Frequency | 3MHz |
RF Energy | 1-100J/cm2 |
IPL Energy | 1~50J/cm2 |
Power Supply Spot Size | Max 2500W |
Filter handpiece: 12*12mm2, 12*30mm2, 13*40mm2, 15*50 mm2 | |
Filter fixed handpiece: 8*40mm2, 14*40mm2, 16*50 mm2 | |
Pulse Number | 1~6T |
Pulse Interval | 1~99ms |
Pulse Width | 0.1~9.9ms |
Discharge Interval | 1~4s |
RF Delay | 1~3s |
Cooling Temperature | -5~5°C |
RF | |
Output Mode | Tripolar |
Energy | 5~450J |
Frequency | 1-40MHz |